| Sign In | Join Free | My bjjsgy.com | 
 | 
Model Number : SO-E2-960
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5000pcs
Delivery Time : 3-5work days
Packaging Details : Paper box
Measuring gas : Oxygen concentration
Measuring medium : Gaseous atmosphere
Measuring principle : Limiting current type sensor
Measuring ranges : 1.00 - 96.0 vol.% O2
Output current : 15 μA - 30 μA
Accuracy : ±1.00 % O2
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.
 SO-E2-960 TO8 Housing, ø 15.3 mm; H= 13.7 mm; pin distance 7.18 mm
Below the advantages of the Zirconia Oxygen Sensor SO-E2-960:
 • Measuring range 1.00 to 96.0 vol.% oxygen
 • High accuracy
 • For many types a more or less linear characteristic
 • Small temperature dependence of the sensor signal
 • Low interference with other gases
 • Long service life
 • In many cases "Single point calibration" necessary only once
 SO-E2-960 Limiting Current Type Zirconia Oxygen Sensors Applications:
 Medical
 • Oxygen Concentrators
 • Incubators
 Laboratory
 • Inert gas processing cabinets (Glove boxes)
 • Incubators (controlled bacterial growth)
 Food industry
 • Packaging
 • Controlled food testing
 • Monitoring fruit ripening processes (storage / transport)
 Household/Gastronomy
 • High-temperature humidity measurements (> 100°C) for baking / roast automation
 Measuring technique
 • Oxygen Meters (stationary / portable)
 • Measurements under controlled O2 content
 • Air conditioning and ventilation
 Security technology/Monitoring
 • Fire protection (increased N2 atmosphere e.g. Server rooms)
 • Greenhouses, wine cellar
 • Gas storage, refineries
 • Diving
 • Fermentation units
 (Electrical-) industry
 • Inert gas processing machines and cabinets
 • Inert gas welding monitoring
 • Storage with increased N2 atmosphere (oxidation prevention)
 • Drying units
 • Nitrogen concentrators
 • Exhaust gas measurement
SO-E2-960 Limiting Current TypeZirconia Oxygen Sensors Characteristic Data:
| Measuring gas | Oxygen concentration | 
| Measuring medium | Gaseous atmosphere | 
| Measuring principle | Limiting current type sensor | 
| Measuring ranges | 1.00 - 96.0 vol.% O2 | 
| Response time (t90) | 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber) | 
| Sensor voltage / heating voltage / power consumption / heater cold resistance | |
| Sensor voltage: Heating voltage: Power consumption: Cold resistance: | 0.7 to 1.6 Volt 3.6 to 4.4 Volts 1.3 to 1.8 Watts (depends on application and packaging) R(25°C) = 3.25Ω ± 0.20Ω | 
| Warm up time | Min. 30 s | 
| Maximum permissible operating temperature | 350°C (*) *Depending on the cable and filter assembly (see paragraph: specification, Cable assembly) | 
| Permissible volumetric flow rate (Purging the sensor) | For all sensor types, the maximum flow rate depends on the way of purging the sensor (sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber. Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow [ml/min]: 100 - 500 (optimal: 250) | 
| Lifetime (MTTF) | ~ 20.000 hours (*) *Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight deviation from the dispatch specifications. | 
| Vibration resistance | Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx, SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests). | 

|   | 
| SO-E2-960 Limiting Current Type Zirconia Oxygen Sensor Images | 
 H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                                                        
                                                        
                        
                        
                        
                                                            H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                    
                        
                     NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                                                    
                        
                        
                        
                                                            NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                    
                        
                     H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                                                    
                        
                        
                        
                                                            H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                    
                        
                     NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                                                    
                        
                        
                        
                                                            NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                    
                        
                     NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection
                                                                                    
                        
                        
                        
                                                            NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection
                                                    
                        
                     NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                                                    
                        
                        
                        
                                                            NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                    
                        
                     SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                                                    
                        
                        
                        
                                                            SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                    
                        
                     GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                                                    
                        
                        
                        
                                                            GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                    
                        
                     SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                                                    
                        
                        
                        
                                                            SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                    
                        
                     TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen
                                                                                        
                                                        
                        
                        
                        
                                                            TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen